Servicezeiten: Montag bis Freitag 9:00-18:00
FM-214-4 - FM-214-4 PANASONIC flow sensor FM200, 10l/minø4,NPN
Vorrätig Top‑Produkt

FM-214-4

FM-214-4 PANASONIC flow sensor FM200, 10l/minø4,NPN

$0.00USD
4052 auf Lager
Wichtige Spezifikationen
Artikel:Specifications
Gewicht:Net weight: 50 g approx., Gross weight: 115 g approx.
Details:Resin body type
Anzeige:4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
GewichtNet weight: 50 g approx., Gross weight: 115 g approx.
DetailsResin body type
Anzeige4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
ProduktIntegrated Display Type Digital Flow Sensor
MaterialEnclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
LinearitätWithin ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
Portgrößeø4 ø0.157 push-in
SchutzIP40 (IEC)
ZubehörCN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
TeilenummerFM-214-4
KabellängeTotal length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
ProduktnameIntegrated Display Type Digital Flow Sensor FM-200
WiederholbarkeitWithin ±1 % F.S.
Externer EingangON voltage: 0 to +0.4 VOFF voltage: +5 V to +V, or openInput time: 80 ms or more
ProduktnummerFM-214-4
Versorgungsspannung12 to 24 V DC ± 10 % Ripple P-P10 % or less
Umgebungsfeuchtigkeit35 to 90 % RH, Storage: 35 to 90 % RH
Geeignete FlüssigkeitClean air, compressed air, nitrogen gas(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
Stoßfestigkeit100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each
VerbindungsmethodeConnector
VergleichsausgabeNPN open-collector transistor・Maximum sink current: 50 mA or less・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)・Residual voltage: 2.4 V or less (at 50 mA sink current)
GehäuseerdungFloating(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Umgebungstemperatur0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
Aktueller VerbrauchNormal mode: 60 mA or less, ECO mode: 40 mA or less
Durchflussrate im Vollausschlag10 ℓ/min.(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
Nenndruckbereich-0.09 to +0.7 MPa
Vibrationsfestigkeit10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or 49 m/s2max. acceleration, in X, Y and Z directions for two hours each
Analoger SpannungsausgangOutput voltage: 1 to 5 V, Output impedance: 1 kΩ approx.[Refer to "Analog voltage output" for more details.]
Isolationswiderstand10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
GenauigkeitssicherungsbereichBi-direction : -100 to -3 % F.S., +3 to +100 % F.S.One-side direction : +3 to +100 % F.S.(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
DruckcharakteristikWithin ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Spannungsfestigkeit1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
Druckbeständigkeit1 MPa
Angegebener integrierter Wert0.1 ℓ
TemperaturcharakteristikWithin ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Vergleichsausgabe: HystereseWindow comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
Einhaltung der CE-KennzeichnungsrichtlinieEMC Directive, RoHS Directive
Vergleich der Ausgänge: AusgabemodiOutput OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Momentaner Durchfluss: Anzeigebereich-11 to +11 ℓ/min.(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
Vergleichsausgabe: Reaktionszeit50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Integrierter Durchfluss: Anzeigebereich±99999.99 ℓ(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
Vergleichsausgang: KurzschlussschutzIncorporated
Momentaner Durchfluss: Einstellung und Anzeigeauflösung0.01 ℓ/min.
Integrierter Durchfluss: Einstellung und Anzeigeauflösung0.01 ℓ

Produktbeschreibung

More details
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top