| Parameter | Wert |
|---|---|
| Plastic body with metal head | |
| Kopf | Stainless steel 316 |
| Artikel | Remarks |
| PFHd | 3.44 × 10-8 |
| Typ | Housing |
| MTTFd | 356 years |
| Festsetzung | 2 × M5, 40 mm distance |
| Material | Body |
| M20 Drüse | Stainless steel 316 for F3S-TGR-KH16 types |
| Standards | EN1088, IEC 60947-5-1, EN 60204-1, UL508EN ISO 13849-1: up to PLe1EN 62061: up to SIL31 |
| Vibration | IEC 68-2-6, 10-55 Hz +1 Hz, Excursion: 0.35 mm, 1 octave/min |
| Kabeleinführung | M20 |
| 3NC Langsame Aktion | F3S-TGR-KM15-30 |
| für Metallkopf | F39-TGR-KAM |
| schwer flexibel | F39-TGR-KHF |
| Befestigungsschrauben | Set of Torx safety screws (M4, 4 × 30 mm, 4 × 20 mm, 4 × 10 mm; incl. washers and Torx bit) |
| flexibler Kunststoff | F39-TGR-KPF |
| Temperaturbereich | -25 to 80°C |
| hygienisch flexibel | F39-TGR-KHFH |
| Horizontale Montage | F39-TGR-KF |
| Gehäuseschutz | IP67 |
| Nutzungskategorie | AC15 A300 3 A |
| Thermischer Strom (Ith) | 5 A |
| Prüfintervall (Lebensdauer) | 35 years |
| Mechanische Zuverlässigkeit B10d | 2.5 × 106operations at 100mA load |
| minimaler Eintrittsradius des Aktuators | 175 mm standard, 100mm flexible |
| Körperabmessungen (B × H × T) | 54 × 88.4 × 34.5 mm |
| Maximale Annäherungs-/Rückzugsgeschwindigkeit | 600 mm/s |
| Reisebewertung für positive Eröffnung | 8 mm |
| Bemessungsisolation/Stehspannungen | 500 VAC/2,500 VAC |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung