| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Ausgabe | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
| Details | Thru-beam type |
| Produkt | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Zubehör | MS-EXL2-2 (Mounting plate): 2 pcs. |
| Schutz | IP67 (IEC) |
| Teilenummer | EX-L212-C5 |
| Produktname | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Wiederholbarkeit | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| Ansprechzeit | 0.5 ms or less |
| Erfassungsbereich | 3 m9.843 ft |
| Produktnummer | EX-L212-C5 |
| Erfassungsobjekt | Opaque object of ø3 mmø0.118 inor more |
| Versorgungsspannung | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Betriebsanzeige | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitterelement | Red semiconductor laser Class 1 (IEC / JIS/ FDA) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 390 μW, Peak emission wavelength: 655 nm0.026 mil) |
| Stoßfestigkeit | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Umgebungsbeleuchtungsstärke | Incandescent light: 3,000 lx or less at the light-receiving face |
| Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Aktueller Verbrauch | Emitter: 10 mA or lessReceiver: 10 mA or less |
| Stabilitätsindikator | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) |
| Empfindlichkeitsregler | - |
| Vibrationsfestigkeit | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Isolationswiderstand | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Ausgabe: Ausgabeoperation | Light-ON / Dark-ON selectable by the output operation switching input |
| Spannungsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Emissionsfleckgröße (typisch) | Approx. 8 × 5.5 mm0.315 × 0.217 in(vertical × horizontal)(at a sensing distance of 1 m)(Note) In the case sensing distance is 3 m9.843 ft, the emission spot size is H 17 × W 11 mmH 0.669 × W 0.433 in(visual reference value). |
| Einhaltung der CE-Kennzeichnungsrichtlinie | EMC Directive, RoHS Directive |
| Ausgang: Kurzschlussschutz | Incorporated (short-circuit protection / inverse polarity protection) |
| Minimales Erfassungsobjekt (typisch) | - |
| Wiederholgenauigkeit (typisch) (senkrecht zur Messachse) | - |
Technische Spezifikationen und Leistungsdaten