| Parameter | Wert |
|---|---|
| -10 °C ... 50 °C (flexible installation) | |
| Tonhöhe | 2.54 mm |
| Allgemein | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Höhe | ≤ 2000 m |
| Abgeschirmt | no |
| Kabellänge | 1 m |
| halogenfrei | yes |
| Produktart | System cable |
| IDC/FLK40 (1) | IDC/FLK14-1 (1) = black |
| IDC/FLK40 (2) | IDC/FLK14-3 (1) = black |
| IDC/FLK40 (3) | IDC/FLK14-1 (2) = brown |
| IDC/FLK40 (4) | IDC/FLK14-3 (2) = brown |
| IDC/FLK40 (5) | IDC/FLK14-1 (3) = red |
| IDC/FLK40 (6) | IDC/FLK14-3 (3) = red |
| IDC/FLK40 (7) | IDC/FLK14-1 (4) = orange |
| IDC/FLK40 (8) | IDC/FLK14-3 (4) = orange |
| IDC/FLK40 (9) | IDC/FLK14-1 (5) = yellow |
| Leitertyp | Assembled, halogen-free round cable |
| IDC/FLK40 (10) | IDC/FLK14-3 (5) = yellow |
| IDC/FLK40 (11) | IDC/FLK14-1 (6) = green |
| IDC/FLK40 (12) | IDC/FLK14-3 (6) = green |
| IDC/FLK40 (13) | IDC/FLK14-1 (7) = blue |
| IDC/FLK40 (14) | IDC/FLK14-3 (7) = blue |
| IDC/FLK40 (15) | IDC/FLK14-1 (8) = violet |
| IDC/FLK40 (16) | IDC/FLK14-3 (8) = violet |
| IDC/FLK40 (17) | IDC/FLK14-1 (10) = white |
| IDC/FLK40 (18) | IDC/FLK14-3 (10) = white |
| IDC/FLK40 (19) | IDC/FLK14-1 (9) = gray |
| IDC/FLK40 (20) | IDC/FLK14-3 (9) = gray |
| IDC/FLK40 (21) | IDC/FLK14-2 (1) = black |
| IDC/FLK40 (22) | IDC/FLK14-4 (1) = black |
| IDC/FLK40 (23) | IDC/FLK14-2 (2) = brown |
| IDC/FLK40 (24) | IDC/FLK14-4 (2) = brown |
| IDC/FLK40 (25) | IDC/FLK14-2 (3) = red |
| IDC/FLK40 (26) | IDC/FLK14-4 (3) = red |
| IDC/FLK40 (27) | IDC/FLK14-2 (4) = orange |
| IDC/FLK40 (28) | IDC/FLK14-4 (4) = orange |
| IDC/FLK40 (29) | IDC/FLK14-2 (5) = yellow |
| IDC/FLK40 (30) | IDC/FLK14-4 (5) = yellow |
| IDC/FLK40 (31) | IDC/FLK14-2 (6) = green |
| IDC/FLK40 (32) | IDC/FLK14-4 (6) = green |
| IDC/FLK40 (33) | IDC/FLK14-2 (7) = blue |
| IDC/FLK40 (34) | IDC/FLK14-4 (7) = blue |
| IDC/FLK40 (35) | IDC/FLK14-2 (8) = violet |
| IDC/FLK40 (36) | IDC/FLK14-4 (8) = violet |
| IDC/FLK40 (37) | IDC/FLK14-2 (10) = white |
| IDC/FLK40 (38) | IDC/FLK14-4 (10) = white |
| IDC/FLK40 (39) | IDC/FLK14-2 (9) = gray |
| IDC/FLK40 (40) | IDC/FLK14-4 (9) = gray |
| AWG-Signalleitung | 26 |
| Kabelwiderstand | ≤ 145 Ω/km (20 °C) |
| Flammbeständigkeit | IEC 60332-1-2 (raw cable) |
| Verbindungsmethode | IDC/FLK socket strip |
| Querschnitt AWG | (converted acc. to IEC) |
| Beständigkeit gegen Öl | can withstand occasional splashes (raw cable) |
| Geeignete I/O-Karte | 6ES7521-1BP00-0AA0 (Sinking mode) |
| Leitermaterial | Tin-plated Cu litz wires |
| Max. Biegezyklen | 5000 (at a radius of ≥ 15x outside diameter) |
| Anzahl der Positionen | 14 |
| Schutzgrad | IP00 |
| Isolationswiderstand | ≥ 20 MΩ*km (20 °C) |
| Anzahl der Verbindungen | 1 |
| Äußere Hülle, Farbe | gray |
| Nominaler Betriebsmodus | 100% operating factor |
| Betriebsspannung (Wechselstrom) | ≤ 30 V AC |
| Betriebsspannung (DC) | ≤ 60 V DC |
| Äußere Hülle, Material | halogen-free (type 2) |
| Leiterquerschnitt | 14x 0.14 mm² |
| Außendurchmesser des Kabels | 5.8 mm ±0.4 mm |
| Stromstärke (pro Pfad, 50 °C) | ≤ 1 A (Uncoiled, see derating) |
| Stromstärke (pro Pfad, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
| Einführ-/Entfernungszyklen | > 50 |
| Drahtdurchmesser inkl. Isolierung | 1 mm ±0.03 mm |
| Umgebungstemperatur (Betrieb) | -40 °C ... 50 °C (fixed installation) |
| Leiterstruktur-Signalleitung | 7x 0.16 mm |
| Anschluss gemäß Standard | based on IEC 60603-13 |
| Umgebungstemperatur (Lagerung/Transport) | -40 °C ... 80 °C |
| Kleinster Biegeradius, feste Installation | 50 mm |
| Schutzgrad (Installationsort) | ≥ IP54 (Installation location) |
| Kleinster Biegeradius, bewegliche Installation | 93 mm |
Technische Spezifikationen und Leistungsdaten