| Parameter | Wert |
|---|---|
| For DC see load limit curve, e.g., the following values: | |
| Typ | block modular |
| Tiefe | 54 mm |
| Breite | 53.6 mm |
| Höhe | 126.1 mm |
| Aktueller Stromverbrauch | max. 280 mA (all relays pick up) |
| Produktart | I/O component |
| Montageart | DIN rail mounting |
| Produktfamilie | Axioline F |
| Versorgungsspannung | 5 V DC (via bus base module) |
| Verbindungsname | Axioline F connector |
| Artikelüberarbeitung | 02 |
| Verschmutzungsgrad | 2 |
| Abstreiflänge | 8 mm |
| Verbindungsmethode | Bus base module |
| Montageposition | any (observe temperature and current derating) |
| Anzahl der Ausgänge | 4 (floating) |
| Lieferumfang | including bus base module and Axioline F connectors |
| Schaltstrom | max. 8 A AC (cos phi = 1) |
| Eingabeadressbereich | 0 Byte |
| Hinweis zu den Abmessungen | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
| Schaltkapazität | max. 2000 VA |
| Getriebegeschwindigkeit | 100 Mbps |
| Maßzeichnung | |
| Hinweis zur Anwendung | Only for industrial use |
| Ausgabeadressbereich | 1 Byte |
| Schaltfrequenz | max. 6 (per minute) |
| Schutzgrad | IP20 |
| Anzahl der Schnittstellen | 2 |
| Überspannungskategorie | III (EN 61010-2-201/UL 61010-2-201), up to 2000 m above sea levelII (EN 61010-2-201/UL 61010-2-201), up to 3000 m above sea level |
| Standardbezeichnung | Ambient conditions |
| Verbindungstechnologie | 2-conductor |
| Kontaktschaltart | N/O contact |
| Mechanische Lebensdauer | 10x 106cycles |
| Erforderliche Parameterdaten | 1 Byte |
| Luftdruck (Betrieb) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Normen/Spezifikationen | IEC 61850-3 |
| Leiterquerschnitt AWG | 24 ... 16 |
| Erforderliche Konfigurationsdaten | 6 Byte |
| Leiterquerschnitt starr | 0.2 mm² ... 1.5 mm² |
| Hinweis zur Verbindungsmethode | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.When selecting the cables, please note that in the case of a small conductor cross section and high current, the terminal point temperature may be up to 30 K above the ambient temperature. |
| Leiterquerschnitt, starr | 0.2 mm² ... 1.5 mm² |
| Umgebungstemperatur (Betrieb) | -25 °C ... 60 °C (max. 6 A/channel for wall mounting on horizontal DIN rail; max. 4 A/channel for any mounting position) |
| Luftdruck (Lagerung/Transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Leiterquerschnitt flexibel | 0.2 mm² ... 1.5 mm² |
| Zulässige Luftfeuchtigkeit (Betrieb) | 5 % ... 95 % (non-condensing) |
| Leiterquerschnitt, flexibel | 0.2 mm² ... 1.5 mm² |
| Prüfspannung: Relaiskontakt / Logik | 4 kV |
| Umgebungstemperatur (Lagerung/Transport) | -40 °C ... 85 °C |
| Zulässige Luftfeuchtigkeit (Lagerung/Transport) | 5 % ... 95 % (non-condensing) |
| Maximale Verlustleistung im Nennbetrieb | 1.4 W |
| Prüfspannung: Relaiskontakt / Funktionsmasse | 4 kV |
| Schaltleistung gemäß IEC 60947-5-1 | 6 A (120 V (AC15)) |
| Prüfspannung: Relaiskontakt/Relaiskontakt (offener Kontakt) | 1 kV, 50 Hz, 1 min. |
| Prüfspannung: Relaiskontakt/Relaiskontakt (benachbarte Stecker) | 2.5 kV |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung