| Parameter | Wert |
|---|---|
| VersionClassificationeClass5.127-20-05-03eClass627-20-05-03eClass7.127-20-05-03eClass827-20-05-03eClass927-20-05-03eClass9.127-20-05-03 | |
| EAN | Not available |
| UPC | Not available |
| eClass | 5.1 |
| Preisgruppe | 8L3 |
| Metallfaktor | None |
| Produktgruppe | 4717 |
| Produktklasse | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Mengeneinheit | 1 Piece |
| Warencode | 90261029 |
| Produktfamilie | Not available |
| Nettogewicht (kg) | 2,000 Kg |
| Ursprungsland | Germany |
| LKZ_FDB/ Katalog-ID | FI01-4 |
| Verpackungsmenge | 1 |
| Verpackungsabmessungen | Not available |
| Produktbeschreibung | Pointek CLS300 - Digital - High Temp Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: Welded flange, 316L stainless steel, raised face: 1 1/2" ASME, 600 lb Probe Length: (Lengths from flange face) Extended rod, length 750 mm (29.53") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP68 Active Shield Length: Extended Shield - (400 mm threaded, 380 mm flanged) |
| Produktlebenszyklus (PLM) | PM300:Active Product |
| Exportkontrollbestimmungen | ECCN : EAR99 / AL : N |
| Standardlieferzeit ab Werk | On request |
| Zuschlag für Rohstoffe | None |
| Verpackungsgröße (Maßeinheit) | Not available |
| Produktabmessungen (B x L x H) | Not available |
| Artikelnummer (Marktnummer) | 7ML5662-5FC00-0HC2 |
| WEEE (2012/19/EU) Rücknahmepflicht | Yes |
| Einhaltung der Stoffbeschränkungen gemäß der RoHS-Richtlinie | Since: 20.07.2017 |
| REACH Art. 33 Informationspflicht gemäß der aktuellen Kandidatenliste | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung