| Parameter | Wert |
|---|---|
| EAN | 4001869528564 |
| UPC | Not available |
| ETIM | 5 |
| UNSPSC | 15 |
| eClass | 6 |
| ● 50 Hz | Yes |
| Gruppencode | P310 |
| Nettogewicht | 632 g |
| ● Amperemeter | No |
| Bestätigung | |
| Datum: 05.02.2022 | |
| Metallfaktor | None |
| Produktgruppe | 5522 |
| Produktklasse | B: return restricted, please contact your Siemens partner/contact |
| Mengeneinheit | 1 Piece |
| ● Voltmeter | No |
| ● Wattmeter | Yes |
| Warencode | 85389091 |
| Produktfamilie | 7KT PAC1200 Measuring Devices |
| Nettogewicht (kg) | 1,941 Kg |
| Ursprungsland | Germany |
| ● Impulszähler | No |
| LKZ_FDB/ Katalog-ID | LV10 |
| Verpackungsmenge | 1 |
| Produktmarkenname | SENTRON |
| Verpackungsabmessungen | 410,00 x 420,00 x 210,00 |
| Produktbeschreibung | Starter kit 24 2x12 sensor bars incl. 24 and 1x data manager |
| Messgenauigkeit | Total accuracy +/-2% (of full-scale value / class 2) |
| Produktbezeichnung | Starter kit |
| Eignung für den Gebrauch | |
| ● Frequenzmesser | Yes |
| Voltmeter (EF006560) | false |
| Design des Produkts | 2x12 with system, 40 A |
| Amperemeter (EF006555) | false |
| Produktlebenszyklus (PLM) | PM300:Active Product |
| Allgemeine Produktzulassung | other |
| Impulszähler (EF006559) | false |
| ● Blindleistungsmesser | Yes |
| Exportkontrollbestimmungen | AL : N / ECCN : N |
| Frequenzmesser (EF006558) | true |
| Standardlieferzeit ab Werk | 5 Day/Days |
| Zuschlag für Rohstoffe | None |
| Blindstromzähler (EF006556) | true |
| Verpackungsgröße (Maßeinheit) | MM |
| Netzfrequenz / Nennwert | |
| Anzahl der Modulbreiteneinheiten | 4 |
| Aktueller Wert / Ausgangswert / Nennwert | 5 A |
| ● Umdrehungsmesser | No |
| Artikelnummer (Marktnummer) | 7KT1223 |
| WEEE (2012/19/EU) Rücknahmepflicht | Yes |
| Mit Drehzahlmesser (EF006557) | false |
| gemessener variabler Strom / Nennwert | 63 A |
| Effektives Leistungsmessgerät (EF006561) | true |
| Regionsspezifische Preisgruppe / Preisgruppe der Zentrale | 15C / 1BK |
| Allgemeine Produktgenehmigung Sonstige Bestätigung Verschiedenes | General Product Approval |
| Einhaltung der Stoffbeschränkungen gemäß der RoHS-Richtlinie | Since: 15.12.2015 |
| REACH Art. 33 Informationspflicht gemäß der aktuellen Kandidatenliste | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dodecachloropentacyclo[12... > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™)covering any of its individual anti- and syn-isomers or any combination thereofBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium trioxi... CAS-No. 12060-00-3 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium trioxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Diboron trioxide CAS-No. 1303-86-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Diboron trioxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung