| Parameter | Wert |
|---|---|
| EAN | 4048879697316 |
| Typ | for 3-wire sensors or mechanical switches, PNP |
| PIN 2 | Input/Output/Diagnostic |
| PIN 4 | Input/Output (port 0...3); IO-Link Master (port 4...7) |
| eClass | 27242604 |
| IO-Link | 4 × Master |
| Gewicht: | 0.38 kg |
| Art.-Nr.: | 5676660 |
| Feldbus | via internal system connection |
| E/A-Anschlüsse | M12 (female) 5-pole, A-coded |
| Lampenlast | 30 W |
| Hafenklasse | Class A + B (not galvanically separated) |
| Schutz | IP69K |
| LED-Anzeige | US: sensor supply (green: OK); IOL: (green: OK); UA: actuator supply (green: OK) |
| Eingangsfilter | 1 ms |
| Spezifikation | IO-Link Master V1.12 |
| Verpackungseinheit | 1 |
| Montageart | 2-hole screw mounting |
| Betriebsarten | COM1; COM2; COM3 (automatic) |
| Aktuatorwarnung | per channel via LED and BUS |
| Kompatibel mit: | 56521; 56526; 56535 |
| Sensorversorgung USA | 24 V DC (EN 61131-2), max. 200 mA (port 0...3); max. 700 mA (port 4...7) |
| Temperaturbereich | 0...+55 °C (storage temperature -20...+75 °C) |
| Ursprungsland | DE |
| Aktuatorversorgung UA | 24 V DC (EN 61131-2), via system connection (max. 4 A) |
| Diagnose über BUS | per module and channel |
| Diagnose über LED | per module and channel |
| Aktueller Verbrauch | max. 100 mA |
| Übertragungsparameter | 32 Byte (per IO-Link port) |
| Kommunikationsstatus | via LED |
| Zolltarifnummer | 85389099 |
| Abmessungen (H × B × T) | 126×30×34.5 mm |
| Überwachung – keine Spannung | yes |
| Überwachung – Unterspannung | yes |
| Kurzschluss und Überlastung | yes |
| Schaltstrom pro Ausgang | max. 1.6 A (short-circuit and overload protected) |
| Sensorsystem-/Aktorversorgung | via internal system connection (max. 2×4 A) |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung