| Parameter | Wert |
|---|---|
| PL | X0, X1, X2, X3 up to e, X7 (PIN 3) up to d |
| UVP | yes |
| PFH | IEC 62061: 4.8E-9 1/h; IEC 61508: 7.8E-10 1/h |
| SIL | X0, X1, X2, X3 up to 3, X7 (PIN 3) up to 2 |
| Typ | for 3-wire sensors or mechanical switches, PNP, IO-Link Devices |
| PIN 2 | Input/Output (port X4, X5); Input (port X6) |
| PIN 4 | Input/Output (port X4, X5); Input (port X6, X7) |
| SIL CL | up to 3 |
| IO-Link | 2× Master |
| Kategorie | X0, X1, X2, X3 up to 4, X7 (PIN 3) up to 3 |
| Feldbus | Ethernet 10/100 Mbit/s; Push Pull RJ45 Data connector |
| E/A-Anschlüsse | M12, 5-pole, A-coded |
| Adressierung | DCP |
| Hafenklasse | 1× Class A; 1× Class B (galvanically separated) |
| Schutz | IP67 |
| Nutzungsdauer | 20 years |
| Gemeinsam genutztes Gerät | yes, for 2 controls |
| Spezifikation | IO-Link Master V1.1.2 |
| Montageart | 2-hole screw mounting |
| Betriebsarten | COM1; COM2; COM3 (automatic) |
| Aktuatorwarnung | per channel via LED and BUS |
| Sensorversorgung USA | 24 V DC (EN 61131-2), max. 700 mA (M12 female), short-circuit and overload protected |
| Temperaturbereich | -20...+60 °C (storage temperature -40...+85 °C) |
| Aktuatorversorgung UA | 24 V DC (EN 61131-2), max. 8 A |
| Diagnose über BUS | per module and channel |
| Diagnose über LED | per module and channel |
| Abmessungen H×B×T | 102×63×225 mm |
| Übertragungsparameter | 32 Byte (In) 32 Byte (Out) per IO-Link port |
| Kommunikationsstatus | via LED |
| Quervernetzungserkennung | Sensor/Actuator |
| Drahtbrucherkennung | yes |
| PROFINET Netload-Klasse | III |
| Überwachung – keine Spannung | yes |
| Überwachung – Unterspannung | yes |
| Kurzschluss und Überlastung | yes |
| Schaltstrom pro Ausgang | max. 2 A (short-circuit and overload protected) |
| Sensorsystem-/Aktorversorgung | Push Pull Power connector, max. 16 A |
| Produktartikelnummer des Herstellers | 5551001 |