Servicezeiten: Montag bis Freitag 9:00-18:00
3VA6560-7KQ32-2AA0 - 3VA6560-7KQ32-2AA0 SIEMENS Circuit breaker 3VA6 UL Frame 800 breaking capacity class C 100kA @ 480 V 3-pole,..
Vorrätig Top‑Produkt

3VA6560-7KQ32-2AA0

3VA6560-7KQ32-2AA0 SIEMENS Circuit breaker 3VA6 UL Frame 800 breaking capacity class C 100kA @ 480 V 3-pole,..

$0.00USD
4450 auf Lager
Wichtige Spezifikationen
:
EAN:4042949437697
EMV:Declaration of Conformity
UPC:804766981197
Lieferanteninformation
SIEMENS
SIEMENS
Produkte: 367174
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
EAN4042949437697
EMVDeclaration of Conformity
UPC804766981197
ETIM7
IDEE4
Tiefe120 mm
andereDangerous Good
Breite210 mm
UNSPSC15
eClass12
Höhe328 mm
GruppencodeP360
Nettogewicht12.76 kg
Tiefe [in]4.72 in
Breite [in]8.27 in
Höhe [in]12.91 in
● maximal600 A
● Mindestens240 A
Bestätigung
MetallfaktorLPB-----
● bei 240 V200 kA
● bei 415 V110 kA
● bei 480 V100 kA
● bei 600 V50 kA
● bei 690 V35 kA
Datum: 25.08.2023Subject to change without notice© Copyright Siemens 2023
Produktgruppe5383
ProduktklasseC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Mengeneinheit1 Piece
● bei 40 °C600 A
● bei 45 °C600 A
● bei 50 °C600 A
● bei 55 °C600 A
● bei 60 °C600 A
● bei 65 °C555 A
● bei 70 °C510 A
Warencode85362090
Produktfamilie3VA Molded Case Circuit Breakers up to 2000 A, UL / IEC
zuletzt geändert:8/14/2023
Nettogewicht (kg)12,760 Kg
Anzahl der Pole3
Produktfunktion
UrsprungslandMexico
Produktkomponente
● Anfangswert120 A
LKZ_FDB/ Katalog-IDLV10
Verpackungsmenge1
ProduktmarkennameSENTRON
● ReiseanzeigeNo
Verpackungsabmessungen250,00 x 360,00 x 180,00
ProduktbeschreibungCircuit breaker 3VA6 UL Frame 800 breaking capacity class C 100kA @ 480 V 3-pole, Line protection ETU860, LSIG, In=600A overload protection, 100% rated Ir=240A ...600A Short-circuit protection Isd=0.6..12x In, Ii=1.5..12x In N conductor protection optionally with external CT up to 160% Ground-fault protection Ig=0.2... 1 x In, tg=0.05-0.8s
Umgebungstemperatur
Betriebsstrom
ProduktbezeichnungMolded-case circuit breaker
● SpannungsauslösungNo
● Vollausschlag600 A
Design des ProduktsSystem protection
Produktlebenszyklus (PLM)PM300:Active Product
Leistungsverlust [W] / maximal151 W
● UnterspannungsauslösungNo
Stromabschaltvermögen
ExportkontrollbestimmungenAL : N / ECCN : EAR99
● KommunikationsfunktionYes
Standardlieferzeit ab Werk25 Day/Days
Zuschlag für RohstoffeNone
Verpackungsgröße (Maßeinheit)MM
● während der Lagerung / maximal80 °C
● während der Lagerung / Mindest-40 °C
● während des Betriebs / maximal70 °C
● während des Betriebs / Minimum-25 °C
● andere MessfunktionenYes
Version zur ErdschlussüberwachungSummation current formation L-conductor
Isolationsspannung / Nennwert800 V
Auslegung der ÜberstromfreigabeETU860
Schutzart IP / an der VorderseiteIP40
Auslegung des N-Leiter-Schutzesadjustable OFF; 20% to 160%
Artikelnummer (Marktnummer)3VA6560-7KQ32-2AA0
WEEE (2012/19/EU) RücknahmepflichtYes
Betriebsspannung / bei Wechselstrom / Nennwert690 V
Produktfunktion / ErdungsschutzYes
Referenzcode / gemäß IEC 81346-2Q
Produktbezeichnung / gemäß UL-DokumentCMAE
Produkterweiterung / optional / MotorantriebNo
Kurzschlussstromauslösevermögen (Icm)
Anzahl der CO-Kontakte / für Hilfskontakte0
Schutzfunktion der ÜberstromauslösungLSIG
Schaltleistungsklasse des LeistungsschaltersC
einstellbarer Einstellstrom (InN) / für N-Auslösung
elektrische Lebensdauer (Betriebszyklen) / bei 480 V5 100
elektrische Lebensdauer (Betriebszyklen) / bei 600 V3 500
Kennzeichnung / gemäß UL 489 / 100 % NennleistungsschalterYes
Regionsspezifische Preisgruppe / Preisgruppe der Zentrale12P / 1CB
Mechanische Lebensdauer (Betriebszyklen) / typisch10 000
maximales Kurzschlussstromausschaltvermögen (Icu)
Betriebskurzschlussstromausschaltvermögen (Ics)
Art des elektrischen Anschlusses / für den Hauptstromkreisnut keeper kit on both ends
einstellbare Verzögerungszeit / des S-Trips / mit I2t-Charakteristik0.5 s
elektrische Lebensdauer (Betriebszyklen) / bei AC-1 / bei 690 V3 500
Einstellbarer Ansprechwert, Einstellstrom (Ii) / für I-Auslösung
Anordnung der elektrischen Steckverbinder / für den HauptstromkreisFront connection
elektrische Lebensdauer (Betriebszyklen) / bei AC-1 / bei 380/415 V5 100
Gesamte Auslösezeit / für G-Auslösung / mit Standardcharakteristik
Einhaltung der Stoffbeschränkungen gemäß der RoHS-RichtlinieSince: 09.07.2019
REACH Art. 33 Informationspflicht gemäß der aktuellen KandidatenlisteLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Silicic acid, lead s... CAS-No. 11120-22-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Silicic acid, lead saltBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Perfluorobutane sulfonic ... > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Perfluorobutane sulfonic acid (PFBS) and its saltsBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
einstellbarer Stromansprechwert Strom / der sofortigen Kurzschlussauslöseeinheit
Einstellbare Ansprechverzögerungszeit (tg) / für G-Auslösung / mit I0t-Charakteristik
Einstellbare Ansprechverzögerungszeit (tg) / für G-Auslösung / mit I2t-Kennlinie
Einstellbare Verzögerungszeit (tr) des Ansprechwerts / für L-Auslösung / mit I2t-Kennlinie
Einstellbare Verzögerungszeit des Ansprechwerts (tsd) / für S-Auslösung / mit I0t-Charakteristik
Einstellbare Ansprechverzögerungszeit (tsd) / für S-Auslösung / mit I²t-Kennlinie
Einstellbarer Ansprechwert, Einstellstrom (Isd) / des S-Trips / mit I0t-Kennlinie
Einstellbarer Ansprechwert, Einstellstrom (Isd) / des S-Trips / mit I2t-Kennlinie
Eignungsbescheinigung / als Zulassung für Marineschiffe (keine Kampfschiffe) / Ergänzung SBYes
Einstellwert des Ansprechstroms (Ir) / des L-Auslösers / mit I2t-Kennlinie
einstellbarer Stromansprechwert / für G-Auslösung / mit Standardcharakteristik
Einstellbarer Ansprechwert, Einstellstrom (Ig) / für G-Auslösung / mit I2t-Kennlinie
Art der anschließbaren Leiterquerschnitte / für Flachstangenanschluss / maximal50 x 28 mm
Art der anschließbaren Leiterquerschnitte / für Flachstangenanschluss / Mindest20 x 4 mm
Leistungsverlust [W] / bei Nennstrom / bei Wechselstrom / im warmen Betriebszustand / pro Pol50.33 W
Produktmerkmale / für Neutralleiter / aufrüstbar/nachrüstbar / kurzschluss- und überlastsicherYes
Auslegung des Lastschalters / gemäß UL 489 / Leitungsschutzschalter für Heizung, Klimatisierung und Kältetechnik (HACR-Typ)Yes
Allgemeine Produktzulassungsbestätigung Sonstiges EMV-Konformitätserklärung Prüfzertifikate Schifffahrts-/Schifffahrtsprüfzertifikate/Prüfbericht Sonstiges Gefahrgutbestätigung Sonstiges Sonstiges TransportinformationenGeneral Product Approval

Produktbeschreibung

circuit breaker 3VA6 UL frame 800 breaking capacity class C 100kA @ 480 V 3-pole, line protection ETU860, LSIG, In=600A overload protection Ir=240A ... 600A short circuit protection. Manufactured to o
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Technische Details

Confirmation

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top