Servicezeiten: Montag bis Freitag 9:00-18:00
3RT1056-6PF35 - 3RT1056-6PF35 SIEMENS power contactor, AC-3 185 A, 90 kW / 400 V AC (50-60 Hz) / DC operation 96-127 V AC/DC..
Vorrätig Top‑Produkt

3RT1056-6PF35

3RT1056-6PF35 SIEMENS power contactor, AC-3 185 A, 90 kW / 400 V AC (50-60 Hz) / DC operation 96-127 V AC/DC..

$0.00USD
4683 auf Lager
Wichtige Spezifikationen
:VersionClassificationeClass627-37-10-03eClass7.127-37-10-03eClass827-37-10-03eClass927-37-10-03eClass9.127-37-10-03ETIM5EC000066ETIM6EC000066ETIM7EC000066ETIM8EC000066IDEA44755UNSPSC1439-12-15-21UNSPSC1539-12-15-29
EAN:4011209510722
UPC:040892698329
ETIM:5
Lieferanteninformation
SIEMENS
SIEMENS
Produkte: 367174
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
VersionClassificationeClass627-37-10-03eClass7.127-37-10-03eClass827-37-10-03eClass927-37-10-03eClass9.127-37-10-03ETIM5EC000066ETIM6EC000066ETIM7EC000066ETIM8EC000066IDEA44755UNSPSC1439-12-15-21UNSPSC1539-12-15-29
EAN4011209510722
UPC040892698329
ETIM5
IDEE4
UNSPSC14
eClass6
GruppencodeR711
MetallfaktorLFO-----
Produktgruppe3706
ProduktklasseC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Mengeneinheit1 Piece
Warencode85364900
ProduktfamilieSIRIUS 3RT contactors, 3-pole, up to 250 kW
Nettogewicht (kg)4,085 Kg
UrsprungslandGermany
LKZ_FDB/ Katalog-IDCC-IC10
Verpackungsmenge1
Verpackungsabmessungen265,00 x 196,00 x 234,00
Produktbeschreibungpower contactor, AC-3 185 A, 90 kW / 400 V AC (50-60 Hz) / DC operation 96-127 V AC/DC auxiliary contacts 1 NO + 1 NC 3-pole, frame size S6 busbar connections drive: electronic with PLC / SIMOCODE - interface and remaining lifetime signal
Produktlebenszyklus (PLM)PM300:Active Product
ExportkontrollbestimmungenAL : N / ECCN : N
Modulare Version (EF001126)true
Standardlieferzeit ab Werk50 Day/Days
Zuschlag für RohstoffeNone
Verpackungsgröße (Maßeinheit)MM
Artikelnummer (Marktnummer)3RT1056-6PF35
Bemessungsbetriebsleistung NEMA (EF011960)110.3248125
Spannungstyp für die Betätigung (EF008242)AC/DC
WEEE (2012/19/EU) RücknahmepflichtYes
Bemessungsbetriebsleistung bei AC-3, 400 V (EF001364)90.0
Bemessungsbetriebsleistung bei AC-4, 400 V (EF008496)90.0
Bemessungssteuerspannung Us bei Gleichstrom (EF003980)['96', '127']
Bemessungsbetriebsstrom Ie bei AC-1, 400 V (EF001393)215
Bemessungsbetriebsstrom Ie bei AC-3, 400 V (EF001392)185
Bemessungsbetriebsstrom Ie bei AC-4, 400 V (EF008495)160
Regionsspezifische Preisgruppe / Preisgruppe der Zentrale41B / 41B
Bemessungssteuerspannung Us bei 50 Hz Wechselstrom (EF003978)['96.0', '127.0']
Bemessungssteuerspannung Us bei 60 Hz Wechselstrom (EF003979)['96.0', '127.0']
Art des elektrischen Anschlusses des Hauptstromkreises (EF006819)-
Anzahl der Hauptkontakte als normalerweise offener Kontakt (EF001374)3
Anzahl der normalerweise geschlossenen Kontakte als Hauptkontakt (EF001375)-
Anzahl der Hilfskontakte als normalerweise offener Kontakt (EF001376)1
Anzahl der Hilfskontakte als normalerweise geschlossener Kontakt (EF001377)1
Einhaltung der Stoffbeschränkungen gemäß der RoHS-RichtlinieSince: 01.05.2012
REACH Art. 33 Informationspflicht gemäß der aktuellen KandidatenlisteLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Perfluorobutane sulfonic ... > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Perfluorobutane sulfonic acid (PFBS) and its saltsBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Produktbeschreibung

SIRIUS Contactor, 90KW/400V/AC-3 drive AC/DC UC 96-127V Auxiliary contacts 1NA+1NC 3 poles, size S6, Bar connections, ELECTRONIC DRIVE With SPS/SIMOCOde INTERFACE and INDICATION OF REMAINING USEFUL LI
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Technische Details

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top