Servicezeiten: Montag bis Freitag 9:00-18:00
3000-33113-3020065 - 3000-33113-3020065 MURRELEKTRONIK MIRO SAFE+ T 1 24
Vorrätig Top‑Produkt

3000-33113-3020065

3000-33113-3020065 MURRELEKTRONIK MIRO SAFE+ T 1 24

$0.00USD
3121 auf Lager
Wichtige Spezifikationen
DC:99% (STOP0); min. 60% (STOP1)
PL:up to e (STOP0); up to d (STOP1)
EAN:4048879367615
SIL:up to 3 (STOP0); up to 2 (STOP1)
Lieferanteninformation
MURRELEKTRONIK
MURRELEKTRONIK
Produkte: 57918
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
DC99% (STOP0); min. 60% (STOP1)
PLup to e (STOP0); up to d (STOP1)
EAN4048879367615
SILup to 3 (STOP0); up to 2 (STOP1)
AC-156 A (230 V AC) STOP0; 3 A (230 V AC) STOP1
DC-135 A (24 V DC) STOP0; 2 A (24 V DC) STOP1
eClass27371819
Art.-Nr.:3000-33113-3020065
Kategorieup to 4 (STOP0); up to 3 (STOP1)
VerbindungSpring clamp plug-in terminals
Nutzungsdauer20 years
Eingangsstrom5.9 VA/2.4 W (with monitoring output)
Eingangsspannung24 V DC (-15 +20%), 24 V AC (-15 +10%)
Verpackungseinheit1
MontageartDIN-rail mountable (EN 60715)
KontaktmaterialAg Sn O, self cleaning, positively driven
Schaltspannungmax. 250 V AC/DC
Temperaturbereich-25...+60 °C (storage temperature -40...+85 °C)
UrsprungslandDE
Mech./ elektr. Leben10 000 000 switching cycles/load dependent
Alternativprodukt:Product Comparison6 A (STOP1); 8 A (STOP0)Protection-door and emergency-stop controlLight curtain controlSafety magnetic switch controlAutomatic/manual/manual monitored reset/startInputInput voltage24 V DC (-15 +20%), 24 V AC (-15 +10%)Input current5.9 VA/2.4 W (with monitoring output)Safety IndicatorsPLup to e (STOP0); up to d (STOP1)Categoryup to 4 (STOP0); up to 3 (STOP1)DC99% (STOP0); min. 60% (STOP1)SILup to 3 (STOP0); up to 2 (STOP1)Service life20 yearsUtilization categorySafety contacts (STOP 0)max. 250 V AC/8 A; min. 5 V AC/5 mA (resist./ind.), at suitable suppressionSafety contacts (STOP 1)max. 250 V AC/6 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppressionAC-156 A (230 V AC) STOP0; 3 A (230 V AC) STOP1DC-135 A (24 V DC) STOP0; 2 A (24 V DC) STOP1General dataMech./ elect. life10 000 000 switching cycles/load dependentConnectionSpring clamp plug-in terminalsMounting methodDIN-rail mountable (EN 60715)Dimensions H × W × D100×22.5×121 mmTemperature range-25...+60 °C (storage temperature -40...+85 °C)OutputSwitching voltagemax. 250 V AC/DCSwitching current per outputmax. 8 A (STOP0); max. 6 A (STOP1)No. of auxiliary contacts0No. of alarm outputs1 - (Y1)No. of safety contacts2 - (13-14), (23-24), STOP0; 1 - (37-38), STOP1Contact materialAg Sn O, self cleaning, positively drivenCommercial datacountry of originDEcustoms tariff number85364900EAN4048879367615eClass27371819Packaging unit1
Anzahl der Alarmausgänge1 - (Y1)
Zolltarifnummer85364900
Abmessungen (H × B × T)100×22.5×121 mm
Anzahl der Sicherheitskontakte2 - (13-14), (23-24), STOP0; 1 - (37-38), STOP1
Sicherheitskontakte (STOP 0)max. 250 V AC/8 A; min. 5 V AC/5 mA (resist./ind.), at suitable suppression
Sicherheitskontakte (STOP 1)max. 250 V AC/6 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppression
Anzahl der Hilfskontakte0
Schaltstrom pro Ausgangmax. 8 A (STOP0); max. 6 A (STOP1)

Produktbeschreibung

MIRO SAFE+ T 1 2424 VAC/DC - 2 N/O contact / 1 N/O contact delayed
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top