Servicezeiten: Montag bis Freitag 9:00-18:00
3000-33113-3020060 - 3000-33113-3020060 MURRELEKTRONIK MIRO SAFE+ T 2 24
Vorrätig Top‑Produkt

3000-33113-3020060

3000-33113-3020060 MURRELEKTRONIK MIRO SAFE+ T 2 24

$0.00USD
3430 auf Lager
Wichtige Spezifikationen
DC:99% (STOP0); min. 60% (STOP1)
PL:up to e (STOP0); up to d (STOP1)
EAN:4048879367592
SIL:up to 3 (STOP0); up to 2 (STOP1)
Lieferanteninformation
MURRELEKTRONIK
MURRELEKTRONIK
Produkte: 57918
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
DC99% (STOP0); min. 60% (STOP1)
PLup to e (STOP0); up to d (STOP1)
EAN4048879367592
SILup to 3 (STOP0); up to 2 (STOP1)
AC-156 A (230 V AC) STOP0; 3 A (230 V AC) STOP1
DC-136 A (24 V DC) STOP0; 2 A (24 V DC) STOP1
eClass27371819
Art.-Nr.:3000-33113-3020060
Kategorieup to 4 (STOP0); up to 3 (STOP1)
VerbindungSpring clamp plug-in terminals
Nutzungsdauer20 years
Eingangsstrommax. 7.1 VA/3.2 W (with monitoring output)
Eingangsspannung24 V DC (-15 +20%), 24 V AC (-15 +10%)
Verpackungseinheit1
MontageartDIN-rail mountable (EN 60715)
KontaktmaterialAg Sn O, self cleaning, positively driven
Schaltspannungmax. 250 V AC/DC
Temperaturbereich-25...+60 °C (storage temperature -40...+85 °C)
UrsprungslandDE
Mech./ elektr. Leben10 000 000 switching cycles/load dependent
Alternativprodukt:Product Comparison6 A (STOP1); 8 A (STOP0)Protection-door and emergency-stop controlLight curtain controlSafety magnetic switch controlAutomatic/manual/manual monitored reset/startInputInput voltage24 V DC (-15 +20%), 24 V AC (-15 +10%)Input currentmax. 7.1 VA/3.2 W (with monitoring output)Safety IndicatorsPLup to e (STOP0); up to d (STOP1)Categoryup to 4 (STOP0); up to 3 (STOP1)DC99% (STOP0); min. 60% (STOP1)SILup to 3 (STOP0); up to 2 (STOP1)Service life20 yearsUtilization categorySafety contacts (STOP 0)max. 250 V AC/8 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppressionSafety contacts (STOP 1)max. 250 V AC/6 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppressionAC-156 A (230 V AC) STOP0; 3 A (230 V AC) STOP1DC-136 A (24 V DC) STOP0; 2 A (24 V DC) STOP1General dataMech./ elect. life10 000 000 switching cycles/load dependentConnectionSpring clamp plug-in terminalsMounting methodDIN-rail mountable (EN 60715)Dimensions H × W × D100×45×121 mmTemperature range-25...+60 °C (storage temperature -40...+85 °C)OutputSwitching voltagemax. 250 V AC/DCSwitching current per outputmax. 6 ATotal current (STOP 0)18 A (45 °C); 15 A (55 °C); 12 A (60 °C)Total current (STOP 1)12 A (45 °C); 10 A (55 °C); 8 A (60 °C)No. of auxiliary contacts1 - (31-32)No. of alarm outputs3 - (13-14); (23-24); (33-34)No. of safety contacts3 - (13-14), (23-24), (33-34), STOP0; 2 - (47-48), (57-58), STOP1Contact materialAg Sn O, self cleaning, positively drivenCommercial datacountry of originDEcustoms tariff number85364900EAN4048879367592eClass27371819Packaging unit1
Anzahl der Alarmausgänge3 - (13-14); (23-24); (33-34)
Zolltarifnummer85364900
Abmessungen (H × B × T)100×45×121 mm
Anzahl der Sicherheitskontakte3 - (13-14), (23-24), (33-34), STOP0; 2 - (47-48), (57-58), STOP1
Gesamtstrom (STOP 0)18 A (45 °C); 15 A (55 °C); 12 A (60 °C)
Gesamtstrom (STOP 1)12 A (45 °C); 10 A (55 °C); 8 A (60 °C)
Sicherheitskontakte (STOP 0)max. 250 V AC/8 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppression
Sicherheitskontakte (STOP 1)max. 250 V AC/6 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppression
Anzahl der Hilfskontakte1 - (31-32)
Schaltstrom pro Ausgangmax. 6 A

Produktbeschreibung

MIRO SAFE+ T 2 2424 VAC/DC - 3 N/O contact / 2 N/O contact delayed
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top